1 PRODUCT FUNCTION
1.4 Turn On/Off Thresholds
12V Solar
Low voltage conditions
(open circuit, tested every
100s)
Turn ON above 12V Turn ON above 17.5V
Turn OFF below 11.9V Turn OFF below 17.2V
Low voltage conditions
(loaded, constantly tested)
Turn OFF instantly below
8V
Turn OFF instantly below
8V
Turn OFF after 20 secs
below 9V
N/A
Over voltage shutdown Turn ON below 15.5V Turn ON below 28V
Turn OFF instantly above
16V
Turn OFF instantly above
29V
Turn OFF after 20 secs
above 15.6V
Turn OFF after 20 secs
above 28.2V
Under voltage shutdown Shutdown if Output Battery < 4V
1.5 External LED Indication
A fl ying lead output (GREEN wire) is provided to connect an external indicator
LED, which can be mounted away from the unit, for example in the vehicle cabin.
The positive lead of the LED will be connected to the indicator output wire (fl ying
lead) provided, and the negative lead of the LED will be connected to the vehicle’s
ground. No external resistors are required.
The remote indicator LED will indicate charging state as described below:
LED State Description
Off constant Not charging
On constant Charging or maintaining charge
4