Redarc BCDC1240-LV Bedienerhandbuch Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
5
1 PRODUCT FUNCTION
1.6 Display Panel
The BCDC1240-LV has three Battery Type Settings available. These settings
enable optimal charging profi les for the auxiliary battery. The battery type
selected is displayed via the LEDs on the front panel in the section ‘Battery Type’.
In addition to the battery type, the status of the charger is indicated via three
LEDs. The ‘Charging Status’ shows when the unit is in BOOST, ABSORPTION
or FLOAT. In order to give more information, the applicable LED will fl ash to
indicate the output by the unit. The longer the fl ash, the more current the charger
is putting out. If the LED is ON solid, then the unit is supplying a full 25A to the
auxiliary battery.
Standby mode is entered when the unit is not charging. In this mode, the Battery
Type LED will blink approx once per second; the charging status LEDs will be off.
In this mode, if the battery type wire is moved then the selected battery type will
update.
1.7 Error Codes
In the event of a fault with the unit, installation, either battery or solar panel,
both the External LED and ALL the LEDs on the unit will fl ash to indicate the
fault type. Flashing sequences are described in the table below.
LED State Description
1 fl ash (1 fl ash followed by 3.5 second off) Internal Hardware Fault
2 fl ash (2 fl ash followed by 3.5 second off) Reserved
3 fl ash (3 fl ash followed by 3.5 second off) Unit over temp fault
4 fl ash (4 fl ash followed by 3.5 second off) Output Battery Fault (Volts too high)
5 fl ash (5 fl ash followed by 3.5 second off) Input under voltage (Battery)
6 fl ash (6 fl ash followed by 3.5 second off) Input over voltage (Battery or Solar panel)
7 fl ash (7 fl ash followed by 3.5 second off) Reverse polarity
Figure 1.6.1 - BCDC1240-LV Front Panel
RoHS
Compliant
BCDC1240
12V 40A DC/DC
3 stage
battery charger
Designed and made in Australia
BATTERY TYPE CHARGE STATUS
AGM/gel
Standard
Calcium
Boost
Absorption
Float